Which two statements are true about the initial storage configuration after the standard (non-virtualized) deployment of a new Exadata Database Machine with High Capacity storage servers?
A. The sparse_
B. There is free space available on the hard disks inside the database servers for possible extension of the /uoi file system.
C. The DATA_
D. There is free space available on flashdisks inside the Exadata storage servers for possible use for storage indexes.
E. There is free space available on flashdisks inside the Exadata storage servers to configure Exadata Smart Flash Logs.
You have been asked by Oracle Support to check the firmware of the hard and flash disks in a storage server. Which cellcli command should you use to get this information?
A. list celldisk attributes name, deviceName, diskType, physicalFirmware
B. list cell attributes name, deviceName, diskType, physicalFirmware
C. list physicaldisk attributes name, deviceName, diskType, physicalFirmware
D. list devices attributes name, deviceName, diskType, physicalFirmware
Your customer needs to ensure that their data is available on the Exadata machine during updates. The customer wants to be able to update one server at a time but still be protected against single-node server failure.
What ASM redundancy level should they use?
A. Normal
B. Sparse
C. High
D. External
E. Extended
You are planning the monitoring configuration for your Exadata X9M Database Machine.
Which three components are monitored directly through the use of Exadata-specific Enterprise Manager Plug-Ins?
A. ASM instances
B. Hybrid Columnar Compression (HCC) ratios on Extended (XT) storage servers
C. the storage server ILOM
D. the Power Distribution Units (PDUs)
E. Oracle clusterware on the database server
F. the RDMA over Converged Ethernet (RoCE) switches
Which two options can be used to identify a damaged or failing flash card on an X9M-2 Database Machine High Capacity storage server?
A. using the CELLCLI CALIBRATE command on the storage server after logging in as the celladmin user
B. using the CELLCLI CALIBRATE command on the storage server after logging in as the root user
C. hardware monitoring using the storage server ILOM
D. using the CELLCLI list LUN DETAIL command as the celladmin user
You are concerned about the operating temperature of the database servers in your Exadata Full Rack and want to be alerted if the server exceeds 30C. What command should use use to generate alerts for such an event?
A. dbmcli -e "set alert ds_temp> 30" on each database server
B. dbmcli -e "set threshold ds_temp comparison=' >', critical=30" on each database server
C. dbmcli -e "alert metriccurrent ds_temp where metricValue > 30" on each database server
D. dbmcli -e "create threshold ds_temp comparison='>', critical=30" on each database server
You are providing oversight for the delivery of a new Exadata Database Machine.
1.
Stabilize the Exadata Rack.
2.
Unpack Oracle Exadata Rack.
3.
Review the safety guidelines.
4.
Let the Exadata acclimatize for 24 hours.
5.
Power on Exadata PDU A.
6.
Place Exadata in its allocated space.
7.
Power on Exadata PDU B.
What is the correct order of these steps?
A. 4,3,2,6,1,7,5
B. 3,2,6,4,1,7,5
C. 2,3,4,6,1,7,5
D. 3,2,6,1,4,7,5
E. 2,6,1,4,3,7,5
Which statement is true about the patching features provided in Platinum Services?
A. Oracle Platinum Service covers Exadata storage software and firmware patching, but customers must perform the database patching.
B. Patching services are available for the full software stack up to twice per year.
C. The rolling and complete down time approaches are two options to patching.
D. Patching is done automatically during business hours.
Which two sections of the AWR report shows statistics for X9M Persistent Memory Cache?
A. PMEM Pool cache Read Hits in the Cache Sizes portion of the Report Summary
B. PMEM Pool Misses in the Exadata Outlier Summary
C. cell PMEM cache Read Hits in the Database IOs portion of the Performance Summary
D. PMEM Cache section within Memory Statistics
E. PMEM Cache section within Exadata Smart Statistics
Examine these commands:
1.
Execute "crscti stop cluster -all" as the grid user from one database server.
2.
Execute "crscti stop cluster -all" as root from one database server.
3.
Power off all network switches.
4.
Execute "crscti stop cluster" as root from one database server.
5.
Execute "crscti stop cluster" as the grid user from one database server.
6.
Power off the rack using the power switches on the PDUs.
7.
Execute "shutdown -h now" on all database servers.
8.
Execute "shutdown -h now" on all Exadata storage servers.
Which is the correct order or the required commands to completely power off an Exadata Database Machine in an orderly fashion?
A. 5, 8, 7, and 6
B. 4, 7, 8, 3, and 6
C. 2, 8, 7, 3, and 6
D. 2, 7, 8, and 6
E. 1, 8, 7, 3 and 6